Manufacturer | Victron Energy | |
MFG NO | PIN482122500 | |
SKU | 6249233 | |
UPC | 8719076054238 |
Phoenix Inverter 48VDC - 1200VA - 120VAC - VE.Direct - NEMA 5-15RThis Phoenix Inverter allows you to power domestic equipment requiring 230V/120V AC - using 'leisure' or 'automotive' batteries rated at 48VDC.VE.Direct Communication Port The VE.Direct Port Can Be Connected To:A computer (VE.Direct to USB interface cable needed)Apple and Android smartphones, tablets, MacBook, and other devices (VE.Direct Bluetooth Smart dongle needed)Fully Configurable:Low battery voltage alarm trip and reset levelsLow battery voltage cut-off and restart levelsDynamic cut-off: load-dependent cut-off levelOutput voltage 210 - 245VFrequency 50 Hz or 60 HzECO mode on/off and ECO mode sense levelMonitoring:In- and output voltage, % load, and alarmsProven ReliabilityThe full bridge plus toroidal transformer topology has proven its reliability over many years. The inverters are short-circuit proof and protected against overheating, whether due to overload or high ambient temperature.High start-up powerNeeded to start loads such as power converters for LED lamps, halogen lamps or electric tools.ECO modeWhen in ECO mode, the inverter will switch to standby when the load decreases below a preset value (min load: 15W). Once on standby, the inverter will switch on for a short period (adjustable, default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.Remote on/offA remote on/off switch can be connected to a two-pole connector, or between battery plus and the left-hand contact of the two-pole connector.LED DiagnosisPlease see the manual for a description.To Transfer the Load to Another AC Source: The Automatic Transfer SwitchFor the low-power inverters, we recommend the Filax Automatic Transfer Switch. The Filax features a very short switchover time (less than 20 milliseconds) so that computers and other electronic equipment will continue to operate without disruption.Inverter Specifications:Cont. Output Power at 25°C: 1200VACont. Output Power at 25°C/40°C: 1000 / 850WPeak Power: 2200WOutput AC voltage / Frequency (adjustable): 230VAC or 120VAC +/- 3% 50Hz or 60Hz +/- 0,1%Input Voltage Range: 9,2 - 17 / 18,4 - 34,0 / 36,8 - 62,0VDC Low Shut Down (adjustable): 9,3 / 18,6 / 37,2VDynamic (load dependent) DC Low Shut Down (fully configurable): Dynamic cut-off, see https://www.victronenergy.com/live/ve.direct:phoenix-inverters-dynamic-cutoffDC Low Restart and Alarm (adjustable): 10,9 / 21,8 / 43,6VBattery Charged Detect (adjustable): 14,0 / 28,0 / 56,0VMaximum Efficiency: 91 / 91 / 92%Zero Load Power: 7 / 8 / 10WDefault Zero-Load Power in ECO Mode (default retry interval: 2,5 s, adjustable): 1 / 1,5 / 3,0WECO Mode Stop and Start Power Setting: AdjustableProtection: a – fOperating Temperature Range: -40 to +65°C (fan-assisted cooling) Derate 1,25% per °C above 40°CHumidity (non-condensing): Max 95%Enclosure Specifications:Material & Color: Steel chassis and plastic cover (blue Ral 5012)Battery-Connection: Screw terminalsMaximum Cable Cross-Section: 35 / 25 / 25mm2 / AWG2 / 4 / 4Standard AC outlets: 230V: Schuko (CEE 7/4), IEC-320 (male plug included) UK (BS 1363), AU/NZ (AS/NZS 3112) / 120V: Nema 5-15R, GFCIProtection category: IP 21Weight: 7,4kg / 16,3lbs Dimensions (h x w x d): 117 x 232 x 327mm / (4.6 x 9.1 x 12.9 inch)Accessories:Remote On-Off: YesAutomatic Transfer Switch: FilaxStandards:Safety: EN-IEC 60335-1 / EN-IEC 62109-1 / UL 458 (3)EMC: EN 55014-1 / EN 55014-2 / IEC 61000-6-1 / IEC 61000-6-2 / IEC 61000-6-3Automotive Directive: ECE R10-4Please contact your dealer for any returns, repairs or support issues related to this product.
Specification | Value | |
---|---|---|
MFG NO | PIN482122500 | |
SKU | 6249233 | |
UPC | 8719076054238 |
Phoenix Inverter 48VDC - 1200VA - 120VAC - VE.Direct - NEMA 5-15RThis Phoenix Inverter allows you to power domestic equipment requiring 230V/120V AC - using 'leisure' or 'automotive' batteries rated at 48VDC.VE.Direct Communication Port The VE.Direct Port Can Be Connected To:A computer (VE.Direct to USB interface cable needed)Apple and Android smartphones, tablets, MacBook, and other devices (VE.Direct Bluetooth Smart dongle needed)Fully Configurable:Low battery voltage alarm trip and reset levelsLow battery voltage cut-off and restart levelsDynamic cut-off: load-dependent cut-off levelOutput voltage 210 - 245VFrequency 50 Hz or 60 HzECO mode on/off and ECO mode sense levelMonitoring:In- and output voltage, % load, and alarmsProven ReliabilityThe full bridge plus toroidal transformer topology has proven its reliability over many years. The inverters are short-circuit proof and protected against overheating, whether due to overload or high ambient temperature.High start-up powerNeeded to start loads such as power converters for LED lamps, halogen lamps or electric tools.ECO modeWhen in ECO mode, the inverter will switch to standby when the load decreases below a preset value (min load: 15W). Once on standby, the inverter will switch on for a short period (adjustable, default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.Remote on/offA remote on/off switch can be connected to a two-pole connector, or between battery plus and the left-hand contact of the two-pole connector.LED DiagnosisPlease see the manual for a description.To Transfer the Load to Another AC Source: The Automatic Transfer SwitchFor the low-power inverters, we recommend the Filax Automatic Transfer Switch. The Filax features a very short switchover time (less than 20 milliseconds) so that computers and other electronic equipment will continue to operate without disruption.Inverter Specifications:Cont. Output Power at 25°C: 1200VACont. Output Power at 25°C/40°C: 1000 / 850WPeak Power: 2200WOutput AC voltage / Frequency (adjustable): 230VAC or 120VAC +/- 3% 50Hz or 60Hz +/- 0,1%Input Voltage Range: 9,2 - 17 / 18,4 - 34,0 / 36,8 - 62,0VDC Low Shut Down (adjustable): 9,3 / 18,6 / 37,2VDynamic (load dependent) DC Low Shut Down (fully configurable): Dynamic cut-off, see https://www.victronenergy.com/live/ve.direct:phoenix-inverters-dynamic-cutoffDC Low Restart and Alarm (adjustable): 10,9 / 21,8 / 43,6VBattery Charged Detect (adjustable): 14,0 / 28,0 / 56,0VMaximum Efficiency: 91 / 91 / 92%Zero Load Power: 7 / 8 / 10WDefault Zero-Load Power in ECO Mode (default retry interval: 2,5 s, adjustable): 1 / 1,5 / 3,0WECO Mode Stop and Start Power Setting: AdjustableProtection: a – fOperating Temperature Range: -40 to +65°C (fan-assisted cooling) Derate 1,25% per °C above 40°CHumidity (non-condensing): Max 95%Enclosure Specifications:Material & Color: Steel chassis and plastic cover (blue Ral 5012)Battery-Connection: Screw terminalsMaximum Cable Cross-Section: 35 / 25 / 25mm2 / AWG2 / 4 / 4Standard AC outlets: 230V: Schuko (CEE 7/4), IEC-320 (male plug included) UK (BS 1363), AU/NZ (AS/NZS 3112) / 120V: Nema 5-15R, GFCIProtection category: IP 21Weight: 7,4kg / 16,3lbs Dimensions (h x w x d): 117 x 232 x 327mm / (4.6 x 9.1 x 12.9 inch)Accessories:Remote On-Off: YesAutomatic Transfer Switch: FilaxStandards:Safety: EN-IEC 60335-1 / EN-IEC 62109-1 / UL 458 (3)EMC: EN 55014-1 / EN 55014-2 / IEC 61000-6-1 / IEC 61000-6-2 / IEC 61000-6-3Automotive Directive: ECE R10-4Please contact your dealer for any returns, repairs or support issues related to this product.
0 | Total: $0.00 |